Research Updates

Back to feed
PubMed

High importance

Oct 13, 2026

OCT Monitoring of Low Energy Long Pulse 1064 nm Nd:YAG Laser Treatment of a Hereditary Hemorrhagic Telangiectasia-Associated Vascular Anomaly.

View original source

Why it matters

This research highlights the potential of OCT as a noninvasive tool for monitoring treatment responses in HHT, potentially guiding more effective laser therapies and improving patient outcomes.

Objective

To evaluate the effectiveness of low energy long pulse 1064 nm Nd:YAG laser treatment for vascular anomalies associated with hereditary hemorrhagic telangiectasia (HHT) using optical coherence tomography (OCT).

Results

The treatment resulted in a clinical improvement with an 89% decrease in vascular density and a shallower vascular plexus depth, confirming successful intervention without adverse effects at lower fluences (50-55 J/cm2).

Methods

A case study involved a 79-year-old female with HHT who received three treatments with the Nd:YAG laser for a vascular lesion. OCT was employed to visualize cutaneous vasculature and monitor treatment effects before and after laser interventions.

Limitations

The study is a single case report, limiting generalizability. Further studies with larger sample sizes are needed to validate these findings across different populations and lesion types.

For your doctor:

PMID: 42871767

DOI: 10.1155/crdm/8810881

Abstract

Hereditary hemorrhagic telangiectasia (HHT) is an autosomal-dominant disorder characterized by vascular lesions with variable treatment responses. Optical coherence tomography (OCT) can provide noninvasive bedside visualization of cutaneous vasculature and monitoring of treatment response. A 79-year-old female with HHT underwent three treatments for a vascular lesion on her right fifth digit that had been resistant to pulsed dye laser, using a long pulse 1064 nm neodymium-yttrium aluminum garnet laser. At lower fluences (50-55 J/cm2), clinical improvement was achieved without adverse effects. OCT imaging performed before and after treatment demonstrated an 89% decrease in vascular density and shallower vascular plexus depth posttreatment. OCT can be used to objectively measure changes in vascular characteristics in response to laser treatment.